Main Page Windows 7 DLLs NirSoft Utilities
Windows 8 DLL File Information - connect.dll

The following DLL report was generated by automatic DLL script that scanned and loaded all DLL files in the system32 directory of Windows 8, extracted the information from them, and then saved it into HTML reports. If you want to view a report of another DLL, go to the main page of this Web site.

 

General Information

File Description: Get Connected Wizards  
File Version: 6.2.9200.16384 (win8_rtm.120725-1247)  
Company: Microsoft Corporation  
Product Name: Microsoft® Windows® Operating System  
DLL popularity Very Low - 1 other DLL files in system32 directory are statically linked to this file.
File Size: 1,252 KB
Total Number of Exported Functions: 15
Total Number of Exported Functions With Names: 15
 

Section Headers

Name Virtual Address Raw Data Size % of File Characteristics Section Contains...
.text 0x00001000 151,552 Bytes 11.8% Read, Execute Code
.data 0x00026000 25,088 Bytes 2.0% Write, Read Initialized Data
.idata 0x0002d000 5,120 Bytes 0.4% Read Initialized Data
.rsrc 0x0002f000 1,076,736 Bytes 84.0% Read Initialized Data
.reloc 0x00136000 23,040 Bytes 1.8% Read, Discardable Initialized Data
 

Static Linking

connect.dll is statically linked to the following files:

msvcrt.dll
netshell.dll
SHELL32.dll
gdiplus.dll
ADVAPI32.dll
SETUPAPI.dll
USER32.dll
ole32.dll
OLEAUT32.dll
USERENV.dll
KERNEL32.dll

This means that when connect.dll is loaded, the above files are automatically loaded too. If one of these files is corrupted or missing, connect.dll won't be loaded.

 

List of files that are statically linked to connect.dll


rasgcw.dll

This means that when one of the above files is loaded, connect.dll will be loaded too. (The opposite of the previous 'Static Linking' section)

 

General Resources Information

Resource Type Number of Items Total Size % of File
Icons 14 1,051,815 Bytes 82.0%
Animated Icons 0 0 Bytes 0.0%
Cursors 0 0 Bytes 0.0%
Animated Cursors 0 0 Bytes 0.0%
Bitmaps 0 0 Bytes 0.0%
AVI Files 0 0 Bytes 0.0%
Dialog-Boxes 16 5,636 Bytes 0.4%
HTML Related Files 0 0 Bytes 0.0%
Menus 0 0 Bytes 0.0%
Strings 58 5,008 Bytes 0.4%
Type Libraries 1 15,904 Bytes 1.2%
Manifest 1 749 Bytes 0.1%
All Others 4 2,410 Bytes 0.2%
Total 94 1,081,522 Bytes 84.3%
 

Icons in this file

There are 14 icons stored in this DLL file. You can view all these icons in the following small thumbnail:
 

Cursors in this file

No cursors found in this file

 

Dialog-boxes list (up to 200 dialogs)

No dialog resources in this file.

 

String resources in this dll (up to 200 strings)

String ID String Text
3050 &Close
3051 &Next
3052 &Set up
3053 &Accept
3054 &Connect
3055 &Skip
3060 Close
3072 Your settings will be saved and you can try to connect later.
3080 This program is not supported in Safe Mode without networking.
3101 Connect to the Internet
3103 Set up a broadband or dial-up connection to the Internet.
3111 Connect to a workplace
3113 Set up a dial-up or VPN connection to your workplace.
3131 Set up a new connection or network
3133 Set up a wireless, broadband, dial-up, hosted network, or VPN connection; or set up a router or access point.
3171 Set up a dial-up connection
3173 Connect to the Internet using a dial-up connection.
3181 Set up a virtual private network (VPN) connection
3183 Connect to your workplace network or another private network.
3301 Connect to the Internet
3311 You are already connected to the Internet
3315 The wizard cannot start your default web browser.
3321 Creating your Internet connection...
3325 The wizard cannot create the connection.
3326 The wizard cannot begin creating the connection.
3331 Testing your Internet connection...
3335 The wizard cannot test the new connection.
3336 The wizard cannot start connection testing.
3341 The Internet connectivity test was unsuccessful
3345 The wizard cannot undo the last created connection.
3391 You are connected to the Internet
3392 The connection to the Internet is ready to use
3401 Connect to a Workplace
3421 Creating the connection...
3431 Setting up the connection...
3435 The wizard cannot start the connection.
3491 You are connected
3492 The connection is ready to use
3493 The wizard cannot connect
3551 Set Up a Connection or Network
3561 Choose a connection option
3571 Create a Dial-up Connection
3581 Create a VPN connection
3611 B&roadband (PPPoE)
3612 Connect using DSL or cable that requires a user name and password.
3621 &Dial-up
3622 Connect using a dial-up modem or ISDN.
3701 Do you want to use a connection that you already have?
3711 How do you want to connect?
3712 Windows did not detect any networking hardware
3721 Windows could not diagnose the problem
3771 To sign up now, choose an ISP offer
3772 Options for finding an ISP
3773 You chose to sign up with the selected ISP
3774 Insert the ISP CD
3791 The wizard cannot start the ISP setup program.
3801 The wizard cannot continue
3810 There are no details available for this problem.
 

COM Classes/Interfaces

Name Type Description
BuildConnectionsOptionsPage CoClass Build Connections Options Page Class  
ConnectToInternetCreationHookPage CoClass Connect To The Internet Creation Hook Page Class  
ConnectToInternetDetectionHookPage CoClass Connect To The Internet Detection Hook Page Class  
ConnectToInternetDiagnosticsHookPage CoClass Connect To The Internet Diagnostics Hook Page Class  
ConnectToInternetFinishPage CoClass Connect To The Internet Finish Page Class  
ConnectToInternetHookPage CoClass Connect To The Internet Hook Page Class  
ConnectToInternetTask CoClass Connect To The Internet Task Class  
ConnectToInternetTestingHookPage CoClass Connect To The Internet Testing Hook Page Class  
ConnectToNetworkPage CoClass Connect To Network Page Class  
ConnectToNetworkTask CoClass Connect To Network Task Class  
ConnectToWorkConnectToInternetPage CoClass Connect To Work Connect To Internet Page Class  
ConnectToWorkCreationHookPage CoClass Connect To Work Creation Hook Page Class  
ConnectToWorkDetectionHookPage CoClass Connect To Work Detection Hook Page Class  
ConnectToWorkExistingConnectionsPage CoClass Connect To Work Existing Connections Page Class  
ConnectToWorkFinishPage CoClass Connect To Work Finish Page Class  
ConnectToWorkHookPage CoClass Connect To Work Hook Page Class  
ConnectToWorkTask CoClass Connect To Work Task Class  
ConnectToWorkTestingHookPage CoClass Connect To Work Testing Hook Page Class  
CreateDialupTask CoClass Create Dial-up Task Class  
CreateVPNTask CoClass Create VPN Task Class  
DisplayConnectionOptionsPage CoClass Display Connection Options Page Class  
DisplayInternetExistingConnectionsPage CoClass Display Internet Existing Connections Page Class  
DisplayWorkExistingConnectionsPage CoClass Display Work Existing Connections Page Class  
HandleDiagnosticsPage CoClass Handle Diagnostics Page Class  
ISPCDPage CoClass ISP CD Page Class  
ISPConfirmPage CoClass ISP Confirm Page Class  
ISPOffersPage CoClass ISP Offers Page Class  
IXWizardHostEvent Interface IXWizardHostEvent interface  
IXWizardMessageEvent Interface IXWizardMessageEvent interface  
IXWizardPageEvent Interface IXWizardPageEvent interface  
IXWizardSource Interface IXWizardSource interface  
IXWizardTaskEvent Interface IXWizardTaskEvent interface  
IXWizardTransactionEvent Interface IXWizardTransactionEvent interface  
MessagePage CoClass Message Page Class  
NetworkTasksHost CoClass Network Tasks Host Class  
 

Exported Functions List

The following functions are exported by this dll:
AddConnectionOptionListEntries CreateVPNConnection DllCanUnloadNow
DllGetClassObject GetInternetConnected GetNetworkConnected
GetVPNConnected HrIsInternetConnected HrIsInternetConnectedGUID
IsInternetConnected IsInternetConnectedGUID IsUniqueConnectionName
RegisterPageWithPage UnregisterPage UnregisterPagesLink

 

Imported Functions List

The following functions are imported by this dll: